产品中心

谷胱甘肽(GSH)酶联免疫吸附检测试剂盒
ELK7846
规格: 价格:
48T ¥1680.00
96T ¥2400.00

Overview 文献

Product name: GSH(Glutathione) ELISA Kit
Reactivity: General
Alternative Names: L-Reduced Glutathione
Assay Type: Competitive Inhibition
Sensitivity: 0.48 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 2h
Research Area: Metabolic pathway;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with GSH protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to GSH. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of GSH in the samples is then determined by comparing the OD of the samples to the standard curve.
  • 日期:2022-03-04 IF:5.118
  • 日期:2022-12-19 IF:4.253
  • 日期:2022-12-22 IF:4.927

标准曲线

Concentration (ng/mL) OD Corrected OD
100.00 0.212
50.00 0.357
25.00 0.567
12.50 0.895
6.25 1.139
3.13 1.585
1.57 1.624
0.00 2.028

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GSH and the recovery rates were calculated by comparing the measured value to the expected amount of GSH in samples.
Matrix Recovery range Average
serum(n=5) 82-94% 88%
EDTA plasma(n=5) 81-97% 89%
Heparin plasma(n=5) 84-97% 90%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GSH and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 79-96% 85-99% 95-104% 82-96%
EDTA plasma(n=5) 85-96% 87-101% 89-97% 85-94%
Heparin plasma(n=5) 98-105% 92-101% 88-102% 87-102%